← Back to list

EMA5-2026-525113042

There is no slip, trip, or fall hazards.

Complete

Asset

Type: Safety
Asset ID: EMA5-General Machinery Safety-1
FC: EMA5 / NO CC/CP

People

Found by: anmgnz@amazon.es
Last update by: ian.thomas@tgw-group.com
Vendor: TGW

Timeline

Identified: 5/25/2026
Last update: 6/18/2026
Completed: 6/18/2026
Verified:

Description

There is no slip, trip, or fall hazards.

Comments history

6/18/2026: (ian.thomas) Completed, black / yellow strip fitted to floor. 
6/1/2026: (okaforug) Team Assigned to has been changed from Amazon Ops Eng to TGW so the status is being reset to Pending 
5/25/2026: (anmgnz) Tripping hazards found due to frame structure.

To avoid trip hazards, the greatest difference between the tops of neighbouring flooring surfaces shall not exceed 4 mm in height, and the gap between two adjacent floorings shall be less than 20 mm, according to Clause 4.2.4.4 of ISO 14122-2. If not possible to re-route or remove the hazard, it shall be properly signed as a hazard with a yellow / black strip according to ISO 3864-1 standard.

Images (3)

EMA5-2026-525113042.Image1.093502.jpg
Defect Pic 1
EMA5-2026-525113042.Image1.093502.jpg
EMA5-2026-525113042.Image2.093502.jpg
Defect Pic 2
EMA5-2026-525113042.Image2.093502.jpg
EMA5-2026-525113042.Image3.060946.jpg
Corrected Pic
EMA5-2026-525113042.Image3.060946.jpg