EMA5-2026-525123335
The actuator of emergency stop device intended to be actuated by hand should be mounted between 0,6 m and 1,7 m above the access leve
Pending
Asset
Type: Safety
Asset ID: EMA5-General Machinery Safety-1
FC: EMA5 /
People
Found by: anmgnz@amazon.es
Last update by: okaforug@amazon.co.uk
Vendor:
Timeline
Identified: 5/25/2026
Last update: 6/1/2026
Completed: —
Verified: —
Description
The actuator of emergency stop device intended to be actuated by hand should be mounted between 0,6 m and 1,7 m above the access leve
Comments history
6/2/2026: (okaforug) Team Assigned to has been changed from Amazon Ops Eng to TGW so the status is being reset to Pending 5/25/2026: (anmgnz) Pull cord installed above 1700mm and also creating a bumping hazard on the nearby stations because of protruding +200mm ISO13850 Clause 4.4.2."The actuator of emergency stop device intended to be actuated by hand should be mounted between 0,6 m and 1,7 m above the access level" Install the tensioning centered outside the conveyor juntion outside the workstation area and reduce the protruding distance to the minimum, aligned with the conveyor structure.