EMA5-2026-525124244
600mm clearance for maintenance activities is granted
Pending
Asset
Type: Safety
Asset ID: EMA5-Conveyor Systems - MHE-1
FC: EMA5 /
People
Found by: anmgnz@amazon.es
Last update by: andrea.sassi@tgw-group.com
Vendor:
Timeline
Identified: 5/25/2026
Last update: 6/17/2026
Completed: —
Verified: —
Description
600mm clearance for maintenance activities is granted
Comments history
6/17/2026: (andrea.sassi) Maintenance access is ensured by removal of the fencing. 6/1/2026: (okaforug) Team Assigned to has been changed from Amazon Ops Eng to TGW so the status is being reset to Pending 5/25/2026: (anmgnz) Crossbelt sorter scan area has not clearance enough to perform maintenance activities. ISO 14122-2:2016, Clause 4.2.2 "Due to the design of the machine, the environment, or the occasional use, e.g. less than 30 days per year and less than two hours per day, the clear width, w, may be reduced from 800 mm to 600 mm" According to Amazon Ergonomics handbook the minimum cleareance for non-routine maintenance activities shall be 600mm. Move the fences aligned with the staris handrail and install a smaller door to allow removing the scanner protections safely.