← Back to list

EMA5-2026-525124244

600mm clearance for maintenance activities is granted

Pending

Asset

Type: Safety
Asset ID: EMA5-Conveyor Systems - MHE-1
FC: EMA5 /

People

Found by: anmgnz@amazon.es
Last update by: andrea.sassi@tgw-group.com
Vendor:

Timeline

Identified: 5/25/2026
Last update: 6/17/2026
Completed:
Verified:

Description

600mm clearance for maintenance activities is granted

Comments history

6/17/2026: (andrea.sassi) Maintenance access is ensured by removal of the fencing. 
6/1/2026: (okaforug) Team Assigned to has been changed from Amazon Ops Eng to TGW so the status is being reset to Pending 
5/25/2026: (anmgnz) Crossbelt sorter scan area has not clearance enough to perform maintenance activities.

ISO 14122-2:2016, Clause 4.2.2 "Due to the design of the machine, the environment, or the occasional use, e.g. less than 30 days per year and less than two hours per day, the clear width, w, may be reduced from 800 mm to 600 mm" According to Amazon Ergonomics handbook the minimum cleareance for non-routine maintenance activities shall be 600mm. Move the fences aligned with the staris handrail and install a smaller door to allow removing the scanner protections safely.

Images (2)

EMA5-2026-525124244.Image1.105020.jpg
Defect Pic 1
EMA5-2026-525124244.Image1.105020.jpg
EMA5-2026-525124244.Image2.105020.jpg
Defect Pic 2
EMA5-2026-525124244.Image2.105020.jpg